Resin Coated Copper Foil
FEATURES
Ÿ Higher glass transition temperature
Ÿ Excellent filling ability
Ÿ Lower dielectric constant
Ÿ Thin dielectric and light weight
Ÿ Easy to drill by CO2 laser
Ÿ Even surface for fine line and space usage
Ÿ Traditional FR-4 processability
Ÿ UL File number E98983(s)
 
PRODUCT THICKNESS
CHARACTERISTICS
UNIT
TYPICAL VALUES
Copper
μm
12 (3/8 oz)
18 (1/2 oz)
36 (1 oz)
Resin Thickness
μm
35 - 110
 
PERFORMANCE LIST
CHARACTERISTICS
UNIT
CONDITIONING
TYPICAL VALUES
Glass Transition Temperature
TMA
160±5
DSC
180±5

Coefficient of Thermal Expansion(Before Tg)

In/in/
TMA
6x10-5~9x10-5
Surface Flatness
μm
-
2-3
Flammability
-
C-24/23/50+E-24/125
V-0
Peel Strength H oz
lb/in
288´10” solder dipping
7-8
Thermal Stress
SEC
288 solder dipping
120 ­
Permittivity 1MHZ
-
C-24/23/50
3.6-3.8
Loss Tangent 1MHZ
-
C-24/23/50
0.02-0.04
Surface Resistivity
MΩ
C-96/35/90
1.0´1011
Volume Resistivity
MΩ-cm
C-96/35/90
3.0´1012
Data shown are nominal values for reference only.
 
DIELECTRIC CONSTANT AND DISSIPATION FACTOR
A. Dielectric Constant ( εr )
1MHz
2MHz
5MHz
10MHz
100MHz
500MHz
1GHz
FR4 -1.6
4.6007
4.5509
4.4014
4.3561
4.2628
4.1641
4.1101
NPRCC
3.7453
3.6973
3.5533
3.4827
3.332
3.2497
3.2231
 
Test Condition : C-24/23/50

B. Dissipation Factor (tand)
1MHz
2MHz
5MHz
10MHz
100MHz
500MHz
1GHz
FR4 -1.6
0.042751
0.037166
0.020411
0.01491
0.011922
0.00887
0.011303
NPRCC
0.0392
0.0373
0.031599
0.028771
0.020463
0.016398
0.016504
Test Condition : C-24/23/50
Measurement Equipment : RF Impedance/Material Analyzer 4291A (Hewlett Packard)
 
THE MANNER OF LAY-UP
 

LAMINATION

Recommended press cycles :
A. 2T2P (2 temperature step / 2 pressure step)
 
 
B. 1T2P (1 temperature step / 2 pressure step)
 
 
C. Vacuum
Vacuum (mmHg)
Time (min)
step 1
760
0
step 2
50
1-5
step 3
50
40-60
 
Suggestions:
1.
Heating rate of material between 70 and 140, 1-3/min is acceptable.
2.
Temperature of material over 170 must be held for at least 40 min to allow epoxy resin to fully cure.
3.
Cooling rate of material should be kept under 2.5/min when the temperature of material is over 100, in order to avoid introducing twist.
4.
A vacuum of less than 50 mmHg will be needed to eliminate voids.